SEAGULL®
IV WATER PURIFIERS- PRODUCT DATA SHEET for United
States Standards
Seagull IV X-1 Water Purifiers · Seagull IV X-2 Water Purifiers ·
Seagull IV X-6 Water Purifiers General
Ecology presents data from testing specifically selected to demonstrate
product effectiveness in removing those contaminants most frequently
encountered in water supplies. Please note that all General Ecology
test results represent performance using actual contaminants, not
substitute surrogates which some companies submit.
This Performance Data Sheet shows some of the removal capabilities
of Seagull IV Water Purifiers. It is recommended that before purchasing
a water treatment unit you have your water supply tested to determine
your actual water treatment needs.
SEAGULL
IV® DRINKING WATER PURIFIERS
Product Brand Name:
- Seagull IV X-1 Drinking Water Purification System-
Configuration B,F,D,P, FP,KF
- Seagull IV X-2 Drinking Water Purification System-
Configuration B,KB,KF
- Seagull IV X-6 Drinking Water Purification System
Manufacturer : Made in USA by General Ecology, Inc.
| Operating Conditions: |
| |
Seagull IV
X-1 purifier |
Seagull IV
X-2 purifier |
Seagull IV
X-6 purifier |
| Housing |
Stainless
Steel Housing |
| Cartridge |
RS-1SG |
RS-2SG |
RS-6SG module |
| Flow Rate
per minute gallons (liters) |
1 gpm (3.8
lpm) |
2 gpm (7.6
lpm) |
6 gpm (23
lpm) |
| Average Capacity
gallons (liters) |
1000 gal.
(3800 ltr.) |
2000 gal.
(7600 ltr.) |
6000 gal.
(23000 ltr.) |
| Operating
Pressure (min psi/ max psi) |
30/
125 |
| Particle Retention
(microns) |
.1
nominal
.4 absolute |
| Temperature
Range F° (C°) |
32°
- 145° (0° to 62°) - do not freeze |
| *Contact
us for additional information on specifications or dimensions.
*Average rated life span, flow rate are based on tested waters,
actual capacity may vary depending on quality of water source.
* Intended for cold water use. Intended for use with Seagull
IV water purifiers. |
Test conditions :
All tests were conducted under standard operating conditions as
previously stated for rated capacity of cartridge/module. The data
are based on documented results from specific testing and are generally
regarded as indicative of the effectiveness to be expected but are
not specific claims of performance.
Contaminant
Tested
Organic Chemicals |
Influent |
Effluent |
Detection
Level ND - None
Detected |
MCL+ |
| 1,1 Dichloroethane |
10 ppb |
ND |
2 ppb |
-- |
| 1,1,2-Trichloroethane |
20 ppb |
ND |
2 ppb |
5 ppb* |
| 1,2-Dibromomethane
(EDB) |
1.9 ppb |
ND |
.2 ppb |
5 ppb |
| 1,4-Dichlorobenzene |
73 ppb |
ND |
NSF Standard
53 |
5 ppb++ |
| 2,4,5-TP (Silvex) |
30.6 ppb |
ND |
.05 ppb |
10 ppb |
| 2,4-D |
338 ppb |
ND |
1 ppb |
70 ppb |
| Aldicarb (Temik) |
228 ppb |
ND |
1 ppb |
7 ppb++ |
| Carbon Tetrachloride |
20 ppb |
0.6 ppb |
|
5 ppb |
| Chlordane |
50 ppb |
ND |
1 ppb |
20 ppb |
| Chlorine Residual |
500 ppb |
ND |
50 ppb |
2.5 ppm (not
an MCL) |
| Chloroform |
300 ppb |
ND |
1 ppb |
-- |
| Dichlorethane |
9.8 ppb |
0.882 ppb |
-- |
5 ppb |
| Diisopropyl
ether |
89 ppb |
ND |
-- |
-- |
| Hexachlorobenzene |
10 ppb |
ND |
.1 ppb |
.1 ppb |
| Methoxychlor |
114 ppb |
<3 ppb |
2 ppb |
40 ppb ** |
| P-chlorobenzene |
10 ppb |
ND |
.1 ppb |
5 ppb proposed
* |
| PCB |
0.05 ppb |
ND |
.01 ppb |
-- |
| Tetrachlorethylene
(PCE) |
73 ppb |
ND |
NSF Standard
53 |
5 ppb |
| Trichloroethylene
(TCE) |
328 ppb |
ND |
NSF Standard
53 |
5 ppb |
| Trihalomethane
Total |
92 ppb |
ND |
1ppb |
100 ppb** |
Contaminant
Tested
Microbiological |
Influent
(colonies/100ml) |
Effluent
(colonies/100ml) |
Detection
Level
(colonies/100ml) ND
- None Detected |
MCL+
(colonies/100ml) |
| Campylobacter
jejuni |
1.6-3.0 x
107 |
ND |
10 |
-- |
| Cryptosporidia |
1.8 x 103 |
ND |
1 |
-- |
| Escherichia
coli |
107 |
ND |
1 |
0/100 ml |
| Fecal Coliform |
103 |
ND |
1 |
0/100 ml |
| Giardia lamblia |
1.13 x 105+++ |
ND |
1 |
-- |
| Klebsiella
terrigena |
4.64 x 108 |
ND |
3 |
-- |
| Listeria monocytogenes |
2.2-2.8 x
107 |
ND |
10 |
-- |
| Polio Virus/Rota
virus |
2.39 x 106 |
ND |
150 |
-- |
| Pseudomonas
aerigompsa§ |
103 |
ND |
1 |
-- |
| Salmonella
typhi§ |
105 |
ND |
1 |
0/100 ml |
| Staphylococcus
aureus§ |
106 |
ND |
1 |
-- |
| Streptococcus
foecalis§ |
105 |
ND |
1 |
-- |
| Vibrio cholerae
inaba§ |
106 |
ND |
1 |
-- |
| Vibrio cholerae
ogawa§ |
106 |
ND |
1 |
-- |
| Yersinia enterocolitica |
2.0-2.8 x
105 |
ND |
10 |
-- |
Contaminant
Tested
Metals |
Influent |
Effluent |
Detection
Level ND - None
Detected |
MCL+ |
| Iron± |
.8 mg/l |
.06 mg/l |
-- |
-- |
| Lead„ |
90 ppb |
ND |
2 ppb |
15 ppb |
| |
| Aesthetics |
Original Well
Water |
Tested Water |
|
|
| Color |
20 |
0 |
-- |
-- |
| Hardness |
72 mg/L |
66 mg/l |
-- |
-- |
| Odor |
abnormal |
normal |
-- |
-- |
| Taste |
abnormal |
normal |
-- |
-- |
| Turbidity |
2 |
0 |
-- |
1.0 |
aesthetic water quality improvement :
Seagull®IV Drinking Water Purification Systems also remove
the following, which some individuals may find offensive in drinking
water: . Chlorine . Foul Tastes . Color . Foul Odors . Turbidity
| Contaminant
Leached |
Testing
Protocol |
Result |
Detection
Level ND - None Detected |
| 1,1,1-Trichloroethane |
NSF
Standard 53 |
ND |
1
ppb |
| 1,1
Dichloroethylene |
NSF
Standard 53 |
ND |
1
ppb |
| 1,2-Dichloroethylene |
NSF
Standard 53 |
ND |
1
ppb |
| Benzene |
NSF
Standard 53 |
ND |
1
ppb |
| Bromodichloromethane |
NSF
Standard 53 |
ND |
2
ppb |
| Bromoform |
NSF
Standard 53 |
ND |
4
ppb |
| Cadmium |
NSF
Standard 53 |
ND |
2
ppb |
| Carbontetrachloride |
NSF
Standard 53 |
ND |
1
ppb |
| Chloroform |
NSF
Standard 53 |
ND |
2
ppb |
| Chromium |
NSF
Standard 53 |
ND |
4
ppb |
| Dibromochloromethane |
NSF
Standard 53 |
ND |
4
ppb |
| Lead |
NSF
Standard 53 |
ND |
1
ppb |
| Mercury |
NSF
Standard 53 |
ND |
.2
ppb |
| Methylene
Chloride |
NSF
Standard 53 |
ND |
1
ppb |
| Phenols |
NSF
Standard 53 |
ND |
10
ppb |
| Tetrachloroethylene |
NSF
Standard 53 |
ND |
1
ppb |
| TOC |
NSF
Standard 53 |
ND |
500
ppb |
| Trichloroethylene |
NSF
Standard 53 |
ND |
1
ppb |
| Trihalomethane
Total |
NSF
Standard 53 |
ND |
2
ppb |
| Vinyl
Chloride |
NSF
Standard 53 |
ND |
1
ppb |
Legend :
+ Maximum Contaminant Level of Federal Standards shown unless
a more rigorous standard is indicated.
++ New York Maximum Contaminant Level is more rigorous than Federal
level.
+++ Total per 500 gallons.
§ Sampled at less than rated capacity.
± Iron will tend to shorten cartridge life.
„ Cartridge used in the test was 1 year 2 months old.
* Journal AWWA, February 1992.
** Water Technology, August 1991.
Note: Seagull®IV purifiers do not remove beneficial dissolved salts
and essential minerals.
Various Federal, State and Local regulations may become known or
change and affect distribution and presentation of performance claims.
All health claims not in compliance with local or state laws are
hereby withdrawn.
installation instructions :
Seagull®IV Drinking Water Purification System X-1/X-2 series
are designed to connect to the cold water supply and also can connect
directly to the main faucet or an auxiliary faucet depending upon
configuration selection. Seagull®IV Drinking Water Purification
System X-6 series installs directly into fresh water supply
line. Please see the Installation And Product Use Instructions for
diagrams and detailed step-by-step directions.
Customer Satisfaction/Money Back Guarantee :
General Ecology, Inc. stands behind the quality and effectiveness
of our Seagull®IV Drinking Water Purification Systems If you
are not fully satisfied with your system, simply return it to the
point of purchase within 30 days, undamaged, for a FULL REFUND of
purchase price.
Standards conformance : Please click "Standards Conformance"
on Test Data page or click here for information.
Manufactured and sold by:
General Ecology, Inc.
151 Sheree Blvd.
Exton, PA 19341 USA
|
 |
|